Mass Flow controlled (MFC) PM10 Monitor in Ambient
Air
|
|
The Brushless Mass Flow Controlled PM10 System includes:
- size selective inlet (<10 micron cut size)
- anodized aluminum shelter
- 8"x10" stainless steel filter holder with probe hole
- brushless blower motor assembly
- continuous flow/pressure recorder
- digital timer and elapsed time indicator
- filter media holder/filter paper cartridge (8"x10")
- brushless mass flow controller with 20/60 scfm air
flow probe
- 110v/60hz or 220v/50hz
|
| Meets EPA
PM10 Code of Federal Regulation, Appendix J to Part 50 |
|
Specifications
|
Flow rate:
36-44cfm (1.02-1.24m3)
|
| Filter
media: Micro-quartz filter media 8" x 10" for
PM10 (TE-QMA) |
| Flow
control: MFC (TE-300-312BL) |
| Motor
blower: Brushless 3-stage motor (TE-117415) |
| Flow
indicator: Flow/Pressure recorder (TE-5009) with
charts (TE-106) |
| Digital
programmable timer: Combination MFC with
digital timer (TE-300-312BL) |
| Elapsed
time indicator device: Digital
elapsed time indicator |
|
Shipping
Information
|
Size/weight:
45.5" x 22.5" x 20"/74 lbs
32" x
32" x 25.5"/56 lbs
(two
cartons) |
Motor
specifications: 110v/60hz-Part
TE-117417 bypass motor
220v/50hz-Part TE-117415 bypass motor, ball bearing,
tangential discharge
Sample delay: 0-11 Days
Running amps: 11 Amps |