Model 10 Hydrocarbon Analyzer
|
FID Single Channel, Spot Heated Total Hydrocarbon Analyzer
|
The VIG Industries, Inc. Model 10 is a microprocessor based, spot heated total hydrocarbon analyzer for high accuracy,
sensitivity and stability. The Model 10 is designed to continuously measure one point.
The Model 10 utilizes a spot heated flame ionization detector (FID).
|
|
Applications:
- Process Monitoring - continuous monitoring and alarm or control of: process gas streams utilizing organic solvents,
crude oil and other chemicals containing hydrocarbons, etc.....
- Efficiency Monitoring - monitoring effluent of V.O.C. reduction for environmental compliance. Efficiency control of
scrubbers, carbon adsorbers, and other abatement equipment.
- Safety Monitoring-L.E.L. (lower explosive limit) - monitoring and/or control personnel work area monitoring, leak detection of process equipment or solvent storage areas.
|
Features:
- Easy to use software
- Automatic ranging
- Automatic fuel and sample shut-off system
- Automatic flame-out indicator
- Adjustable alarm
- Precision 1% of full scale
- Fast response - within one second to 90% of full scale
- Two stage sample filter with exchangeable stainless steel elements
- Teflon? isolated detector
- 19" rack or bench mount
- Sample pump
- Outputs 0-1, 0-5, or 0-10Volts
|
Options:
- Zero and calibration input ports
- 4-20mA output - no extra charge
- Automatic ignition
- User selectable fuel (hydrogen or hydrogen/helium)
- Range recognition relays
- Multi-point sequencer
- Automatic calibration
- RS-232 interface
- Second concentration level alarm
- Internal combustion air supply
- External zero air generator
- Internal dilution system
- Purge and internal cleaning system
- Automatic purge
- NEMA rated enclosures
|
Specifications
|
|
Analysis Method: Flame Ionization Detector (FID)
|
|
Precision:
+/- 1% of Full Scale
|
|
Response Time:
Within 1 Second to 90% of Full Scale
|
|
Zero Drift:
+/- 1% of Full Scale Per 24 Hours
|
|
Span Drift:
+/- 1% of Full Scale Per 24 Hours
|
|
Linearity:
Within 1%
|
|
Oxygen Synergism:
Within 1% of Selected Range
|
|
Ranges:
0-100, 1000, 10000, 100000
|
|
Display:
Backlit Digital / Graphical LCD
|
|
Outputs:
Both 4-10mA & 0-1, 5, or 10 Volts
|
|
Alarms:
Flame Out & Concentration, Latching
|
|
Safety:
Flame Out Indicator with Fuel & All Input Gasses Shut-Off System
|
|
Sample Pump:
6 Liters/Minute or 14 Liters/Minute
|
Operating Requirements
|
|
Fuel:
Hydrogen (UHP Grade) or Hydrogen/Helium (40/60 UHP Grade) Upon Request @ 18PSI
|
|
Combustion Air:
Zero Grade Air @ 10PSI
|
|
Operation Air:
Compressed Air (Instrument Air - Dry / Oil Less) @ 60PSI
|
|
Zero Gas:
Zero Air (UHP Grade) @ 10PSI
|
|
Calibration Gas:
User Selected @ 10PSI
|
|
Power:
115Vac, 60Hz or 220Vac, 50Hz
|
|
Ambient Temperature:
32 to 110? F
|
|
Dimensions:
19"W x 18"D x 7"H
|
|
Weight:
55 LBS
|
Warranty
|
|
All instruments sold by VIG Industries, Inc., are warranted for a period of one (1) year from the date of purchase, against
defects in materials and workmanship. VIG warrants that the product supplied conforms to the specifications assigned
thereto. There is no other warranty either implied or expressed. Seller liability is limited specifically to the cost or assigned
value of the items sold.
|