California Analytical Model 100 Carbon Monoxide
Analyzer
The California Analytical Model 100 CO analyzer uses a non-dispersive
infrared detector coupled
with interferant gas filters. These filters reduce the effects of other
gases that absorb infrared
light at the same wavelength as the gas in question. Calibration values
are adjusted via the zero
and span pot knobs. The Model 100 offers two selectable ranges.
 |
Manufacturer
California Analytical Instruments
Analysis Method
(NDIR) Nondispersive infrared
Range
0-500/ 2,500 ppm
Response Time
90 % of full scale in < 5 secs.
Sample Flow Rate
0.5 to 2 litres/min.
Noise
< 1 % of full scale
Zero & Span Drift
<1 % of full scale per 24 hours
Analog Output
0 to 10 VDC and 4 to 20 mA
Power
115 VAC
Dimensions
5 1/4 " H, 19 " W, 8 " D
Weight
24 lbs. |
California Analytical Model 3300A Carbon Monoxide
Analyzer
The California Analytical Model 3300A CO analyzer uses a non-dispersive
infrared detector coupled with interferant gas filters. These filters reduce
the effects of other gases that absorb infrared light at the same wavelength
as the gas in question. Calibration values are adjusted via the zero and
span pot knobs. The Model 3300A offers three selectable ranges.
 |
Manufacturer
California Analytical Instruments
Analysis Method
(NDIR) Non-dispersive infrared
Range
0-1, 2.5, 5 %
Response Time
90 % of full scale in < 1 seconds
Sample Flow Rate
0.5 to 2 litres /minute
Noise
< 0.5 % of full scale
Zero & Span Drift
<1 % of full scale per 24 hours
Analog Output
Simultaneous 0.1, 1.0, 5.0,
10.0 VDC, 4 -20 mA DC
Power
115 VAC
Dimensions
5 1/4 " H, 19 " W, 16 " D
Weight
30 lbs. |
Thermo Environmental Model 48 C/H Carbon Monoxide
Analyzer
The Thermo Model 48 CO analyzer uses a gas filter correlation / non-dispersive
infrared detector.
The gas filter technique reduces instrument cross sensitivity to similar
gases. Calibration values
are adjusted via the zero and span thumb wheels or microprocessor (depending
on the model).
The model 48C offers ranging up to 30,000 ppm and the 48H offers ranging
up to 50,000 ppm.
 |
Manufacturer
Thermo Environmental Instruments
Analysis Method
Gas filter correlation
Range
0- 30,000 ppm and 0- 50,000 ppm
Precision
1 % of reading or 0.05 ppm
Zero Drift
< 0.1 ppm in 24 hrs..
Span Drift
+/- 1 % full scale in 24 hrs..
Sample Flow Rate
1 litre/minute
Analog Output
Selectable voltage and RS-232
Power
115 VAC
Dimensions
16.75" by 8.62" by 23"
Weight
45 lbs. |
API Model 300 Carbon Monoxide Analyzer
The API Model 300 CO analyzer uses a gas filter correlation / non-dispersive
infrared detector.
The gas filter technique reduces instrument cross sensitivity to similar
gases. Calibration values
are adjusted via the microprocessor controls. The Model 300 offers
excellent sensitivity and has
user defined ranging of up to 1,000 ppm.
 |
Manufacturer
Advanced Pollution Instrumentation (API)
Analysis Method
Gas filter correlation / NDIR
Range
0 - 1,000 ppm
Zero Noise
0.025
Zero Drift
< 0.1 ppm in 24 hrs..
Span Drift
< 1 % full scale in 24 hrs..
Response Time
< 60 secs..
Sample Flow Rate
1 litre/minute
Analog Output
0 - 1, 5, 10 VDC and 4 to 20 mA
Power
115 VAC
Dimensions
17" by 7" by 25"
Weight
50 lbs. |
|