Model 300E
Gas Filter Correlation CO Analyzer
The Model 300E measures low ranges of carbon monoxide by comparing
infrared energy absorbed by a sample to that absorbed by a reference
gas according to the Beer-Lambert law. This is accomplished with a Gas
Filter wheel which alternately allows a high energy light source to
pass through a CO filled chamber and a chamber with no CO present. The
light path then travels through the sample cell, which has a folded
path of 14 meters.
The energy loss through the sample cell is compared with the span
reference signal provided by the gas filter to produce a signal
proportional to concentration, with little effect from interfering
gases within the sample. This design produces excellent zero and span
stability and a high signal to noise ratio allowing extreme
sensitivity. Multi-tasking software gives real time indication of
numerous operating parameters and provides automatic alarms if
diagnostic limits are exceeded.
Built-in data acquisition and internal memory allows logging multiple
parameters including average and instantaneous values, calibration data
and operating parameters. Stored data are easily retrieved through the
serial port or optional Ethernet port via our APIcom software or from
the front panel, allowing operators to perform predictive diagnostics
and enhanced data analysis by tracking parameter trends.
The Model 300E features rugged construction and is designed to perform
with a minimum of attention. In the event maintenance is required,
modular construction makes service a simple operation.
Features:
- Ranges, 0-1 ppm to 0-1000 ppm, user selectable
- Gas Filter Wheel for CO specific measurement
- 14 meter path length for sensitivity
- Microprocessor controlled for versatility
- Multi-tasking software allows viewing of test variables
during operation
- Continuous self checking with alarms
- Bi-directional RS-232 for remote operation
- Digital status outputs indicate instrument operating
condition
- Adaptive signal filtering optimizes response time
- GFC wheel guaranteed against leaks for 5 years
- Temperature & Pressure compensation
- Internal data logging with 1 min to 365 day multiple
averages
- APIcom remote operation software
| Specifications: |
| Ranges: |
0-1 ppm to
0-1,000 ppm full scale, user selectable; Dual ranges and auto ranging
supported |
| Units: |
ppb, ppm,
µg/m3, mg/m3 |
| Zero noise: |
< 0.02 ppm |
| Span noise: |
< 0.5% of
reading above 5 ppm (RMS) |
| Lower Detectable
Limit (LDL): |
0.04 ppm |
| Zero drift: |
< 0.1
ppm/24 hours, 0.2 ppm/7 days |
| Span drift: |
< 0.5% of
reading/24 hours, 1% of reading/7 days |
| Lag time: |
10 seconds |
| Rise and Fall
Time: |
< 60
seconds to 95% |
| Linearity: |
1% of full scale |
| Precision: |
0.5% of reading |
| Sample Flow Rate: |
800 cm3/min
±10% |
| Operating
Temperature Range: |
5 - 40°
C (with EPA equivalency) |
| Dimensions
(HxWxD): |
7”
(178 mm) x 17” (432 mm) x 23.5” (597 mm) |
| Weight: |
40 lbs (18 kg) |
| Power: |
100V - 120V,
220V - 240V, 50/60 Hz, 250W |
| Analog outputs: |
10V, 5V, 1V,
0.1V, selectable |
| Recorder Offset: |
±10% |
| Serial Outputs: |
Serial Port 1:
RS-232 (DB-9M)
Serial Port 2: standard RS-232 or optional RS-485 (DB-9F), Ethernet |
| Status (Digital): |
8 outputs, 6
inputs (opto-isolated), 4 alarm outputs (optional) |
| Current Output: |
Optional 4-20mA,
select up to three channels |
| Approvals: |
USEPA
RFCA-1093-093, MCERTS certified Sira MC050069/00 |
|
|